Volume 16, Issue 3 (Occupational Medicine Quarterly Journal 2024)                   tkj 2024, 16(3): 15-26 | Back to browse issues page

Ethics code: IR.SBMU.PHMS.REC.1402.038


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shahsavani A, Mohseni-Bandpei A, Rahmatinia M, Fallah S A. Investigating the concentration and health risk assessment of bioaerosols in the surgery centers and hospital operating rooms of Shahid Beheshti University of Medical Sciences. tkj 2024; 16 (3) :15-26
URL: http://tkj.ssu.ac.ir/article-1-1316-en.html
Shahed Beheshti University of Medical Sciences , HSE9865@gmail.com
Full-Text [PDF 1193 kb]   (233 Downloads)     |   Abstract (HTML)  (482 Views)
Full-Text:   (257 Views)
Investigating the concentration and health risk assessment of bioaerosols in the surgery centers and hospital operating rooms of Shahid Beheshti University of Medical Sciences
Shahsavani A1 , Band-pay Mohseni A2 , Rahmatinia M3, Fallah SA4[*]
1Associate Professor, Department of Environmental Health Engineering, School of Health and Safety, Shahd Beheshti University of Medical Sciences, Tehran, Iran
2Full Professor, Department of Environmental Health Engineering, Faculty of Health and Safety, Shahed Beheshti University of Medical Sciences, Tehran, Iran
3PhD in Environmental Health Engineering, Air Quality and Climate Change Research Center, Health and Environmental Sciences Research Institute, School of Health and Safety, Tehran, Iran
4Student of the Advanced Public Health (MPH) course, majoring in environmental health, Faculty of Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Abstract
Introduction: Due to the special conditions in operating rooms, infection control is important to maintain health. So, the aim of this study was to survey of air exchange rate/changes per hour (ACH) and health risk assessment of bioaerosols in the surgery center or hospital operating rooms.
Materials and Methods: The results of measuring of bioaerosols by pollution measurement companies were used, in 1401. In 1402, 10 operating rooms were randomly selected and the reliability of the results was examined for these two years. Sampling and analysis of the samples was provided based on the NIOSH 0800 method and ACH were measured by a anemometer. The relationship between the number of bioaerosols and ACH, and also, the reliability between results were calculated with the PCC and the ICC test, respectively, in SPSS-V22 software. The health risk assessment and the probability of risk were estimated by Monte Carlo simulation, in Crystal Ball software.
Results: Among 62 operating rooms, the average number of bacterial and fungal colonies was 69.73±14.59 CFU/m3 and 21.67±4.52 CFU/m3, respectively, which is less than the recommended limit of WHO. The average ACH was 19.67±2.18 per hour. No significant relationship was observed between ACH and the number of colonies (p-value ≥ 0.05). Risk assessment for bacteria and fungi were at an acceptable level and the concentration of bioaerosols was recognized as the most sensitive variable influencing the risk.
Conclusion: Increasing ACH will not lead to a reduction in the load of bioaerosol pollution in operating rooms, which can be very important in the management of reducing energy consumption.
Keywords: Bioaerosols; Bacteria; Fungus; Air exchange rates; Risk assessment
This paper should be cited as:
Shahsavani A, Band-pay Mohseni A, Rahmatinia M, Fallah SA. Investigating the concentration and health risk assessment of bioaerosols in the surgery centers and hospital operating rooms of Shahid Beheshti University of Medical Sciences. Occupational Medicine Quarterly Journal. 2024; 16(3): 15-26.
 
* Corresponding Author:
Email: HSE9865@gmail.com
Tel: +98 2188547894
Received: 02.07.2024                             Accepted: 02.10.2024
Type of Study: Research | Subject: Chemical agents
Received: 2024/07/2 | Accepted: 2024/10/1 | Published: 2024/10/31
* Corresponding Author Address: Department of Environmental Health Engineering, Faculty of Health and Safety, Shahed Beheshti University of Medical Sciences, Tehran, Iran

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Occupational Medicine Quarterly Journal

Designed & Developed by : Yektaweb