<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Occupational Medicine Quarterly Journal</title>
<title_fa>فصلنامه علمی تخصصی طب کار</title_fa>
<short_title>tkj</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tkj.ssu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-7189</journal_id_issn>
<journal_id_issn_online>2251-8274</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>آنالیز حوادث فرآیندی ناشی از نشتی گاز هیدروژن سولفید از واحد لخته‌گیری یکی از پالایشگاه‌های پارس جنوبی با رویکرد تعیین حریم ایمن</title_fa>
	<title>Analysis of Processing Accidents due to H2S in Clot Stuck Unit of one of the South Pars Refineries Leakage Using Determination of Safe Privacy Approach</title>
	<subject_fa>ایمنی و حوادث ناشی از کار</subject_fa>
	<subject>Safety and occupational accidents</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مقدمه&lt;/strong&gt;: پالایشگاهها به&#8204; خاطر ارتباط تنگاتنگ با مواد، محصولات و فرآیندهای تولیدی خطرناک معمولاً بسترگاه بسیاری از حوادث و اتفاقات هستند. هدف از این مطالعه، آنالیز پیامد سناریوی نشتی گاز هیدروژن سولفید از واحد لخته&#8204;گیری&amp;nbsp; پالایشگاه گازی فاز 2 و 3 پارس جنوبی و تعیین مرز خطر و حد آسیب&#8204;رسانی این سناریو می&#8204;باشد&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;روش بررسی&lt;/strong&gt;: مطالعه صورت گرفته بصورت توصیفی تحلیلی و بطور مقطعی در پالایشگاههای گازی 2 و 3 پارس جنوبی صورت گرفت جهت ارزیابی چگونگی پخش و تأثیرگذاری سناریوی نشتی از نرم&#8204;افزار &lt;span dir=&quot;LTR&quot;&gt;PHAST&lt;/span&gt; نسخه 54/6 استفاده شد. برای این کار ابتدا سناریوهای مختلف نشتی را در این شرایط تعیین و سپس نسبت به شناسایی شرایط آب و هوایی تأثیرگذار در این سناریو اقدام گردید و در نهایت پیامدهای این سناریوها تعیین و مرز خطر و حد آسیب&#8204;رسانی این سناریو برای نواحی تأثیرگذار و نواحی تحت تأثیر، در 2 سطح معیار&lt;span dir=&quot;LTR&quot;&gt; LC&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;IDLH&lt;/span&gt; مشخص گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتایج&lt;/strong&gt;: نتایج این مطالعه نشان داد که فاصله خطر، بر حسب متر در خصوص معیار&lt;span dir=&quot;LTR&quot;&gt; LC&lt;/span&gt;&lt;sub&gt;&lt;span dir=&quot;LTR&quot;&gt;50&lt;/span&gt;&lt;/sub&gt;&lt;span dir=&quot;LTR&quot;&gt; for H2S Toxic Dispersion&lt;/span&gt;برای محدوده تأثیرگذار(&lt;span dir=&quot;LTR&quot;&gt;Restricted&lt;/span&gt;) برابر با 224 متر و فاصله خطر درخصوص معیار &lt;span dir=&quot;LTR&quot;&gt;IDLH for H2S Toxic Dispersion&lt;/span&gt; برای نواحی تحت تأثیر(&lt;span dir=&quot;LTR&quot;&gt;Impacted area&lt;/span&gt;) برابر با 386 متر می&#8204;باشد. همچنین نتایج مطالعه نشان داد که کمپ &lt;span dir=&quot;LTR&quot;&gt;ENI &lt;/span&gt;&amp;nbsp;در فاصله 200 متری از فنس فاز 2 و 3 و در جهت جریان غالب بوده و در صورت وقوع نشتی آسیب انسانی فراوانی حاصل خواهد گردید. لذا بایستی سریعاً نسبت به تغییر مکان محل اسکان نیروها در کمپ و یا اتخاذ تدابیر کنترلی مهندسی اقدام فوری نمود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری&lt;/strong&gt;: با بکارگیری اطلاعات مربوط به خطرات و نتایج آنالیزهای صورت گرفته و ارزیابی پیامدها در قالب تعیین محدوده خطر می&#8204;توان با بکارگیری نرم&#8204;افزارهای ارزیابی، جمعیتی میزان ریسک جمعی این سناریوهای فجایع را تعیین نمود و در قالب چنین مطالعه&#8204;ای، نواحی و جمعیت تحت تأثیر مخاطرات صنعتی را از آسیب، رهایی داد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;واژه&#8204;های کلیدی&lt;/strong&gt;:&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;&lt;em&gt;Introduction&lt;/em&gt;&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; Refineries are considered as the base of many accidents and incidences due to their close proximity with dangerous substances, products, and production processes. This study analyzed the consequences of H&lt;sub&gt;2&lt;/sub&gt;S leakage scenario from clot stuck unit of South Pars Gas Refinery and determined the dangerous boundaries and the risk limits of this scenario.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;em&gt;Methods&lt;/em&gt;&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; This was a descriptive cross-sectional study. It was carried out in gas refineries of South Pars Phases 2 and 3. To evaluate the gas dispersion modality and the effectiveness of leakage scenario, the PHAST 6.53.1 software was used. To do so, firstly, the different scenarios of leakage were determined under these conditions, and then different climatic conditions affecting these scenarios were identified. Ultimately, the consequences of these scenarios were determined and these dangerous boundaries and risk limits of these scenarios for the effective and impacted areas were determined at two-level criteria of the LC and IDLH.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;em&gt;Results&lt;/em&gt;&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; The findings of this study demonstrated that distance risk of LC&lt;sub&gt;50&lt;/sub&gt; for H&lt;sub&gt;2&lt;/sub&gt;S Toxic dispersion for the restricted areas was 224 m and the distance risk of the IDLH for H2S Toxic dispersion for the impacted area was 386 m, respectively. Also, the results revealed that the ENI camp was in the dominant current direction in the distance of 200 m from phases 2 and 3. In the case of occurrence of leakages, many human damages and losses would happen. Consequently, it is mandatory to change the place of residence of camp inhabitants and immediately take appropriate engineering control measures.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;em&gt;Conclusion&lt;/em&gt;&lt;/strong&gt;&lt;strong&gt;:&lt;/strong&gt; Using the data related to hazards and considering the results of the conducted analysis, and also assessing the consequences in the frame of risk limit, the collective risks of these disaster scenarios could be determined by the use of population assessment software.&lt;/p&gt;
</abstract>
	<keyword_fa>حوادث فرآیندی, پالایشگاه, نواحی تأثیرگذار, نواحی تحت تأثیر</keyword_fa>
	<keyword>Process Accidents, Refinery, Restricted Area, Impacted Area</keyword>
	<start_page>11</start_page>
	<end_page>18</end_page>
	<web_url>http://tkj.ssu.ac.ir/browse.php?a_code=A-11-36-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Ebrahemzadih</last_name>
	<suffix></suffix>
	<first_name_fa>مهرزاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابراهیم زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Farshad </first_name>
	<middle_name></middle_name>
	<last_name>Foroghi nasab</last_name>
	<suffix></suffix>
	<first_name_fa>فرشاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فروغی نسب</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Mortazavi</last_name>
	<suffix></suffix>
	<first_name_fa>مرتضی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مرتضویی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>R</first_name>
	<middle_name></middle_name>
	<last_name>Soltani gerdefaramarzi</last_name>
	<suffix></suffix>
	<first_name_fa>رضیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سلطانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی  شهید صدوقی یزد</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
