Abstract:   (6675 Views)
Background: Decontamination is a process that infectious organisms are removed by physical and chemical methods. The advantages and disadvantages of each of these values can lead to a clear viewpoint of an appropriate sterilization process. The aim of this study was to investigate the effectiveness of 70% alcohol, Deconex (SOLARSEPT) and H2O2, also the additive effect of supplemental UV light on decontamination of laboratory items. Methods: The rates of contaminations of laboratory equipment’s and surface areas were assessed before and after exposure with mentioned chemicals and in the final stage by UV light. Overall the 12 laboratory equipment and the 7 office instrument were evaluated. The UV light was used for 40 min from distance of 2.5 meter. Then, all points were sampled after decontamination and the microbial plates were incubated for microbial colony counts after 48h. Results: The number of colonies before disinfection stage was 26.43 colonies per unit (cfu) in administrative and 15.17 in laboratory equipment. After using UV, H2O2, ethanol and Deconex, the numbers of colonies were reduced to 2.57, 0.4, 1.29 and 0.71, respectively (p <0.05). Simultaneous use of H2O2 and Deconex with UV light reduced the numbers of colony to 0.14 and 0.17. In the administrative equipment’s, the number of colonies after H2O2, ethanol, deconex and UV light were 0, 1.67, 1.25 and 0.83, respectively. Also, combination of UV with deconex and H2O2 reduced the colony formation to zero. Conclusion: H2O2 was effective on reducing the number of colonies. Due to low toxicity, it is recommended to be used in infertility lab. We must make sure that application of disinfection chemicals will not interfere with the laboratory experiments and limits the threat to health of staff.
Full-Text [PDF 188 kb]   (17093 Downloads)    
Type of Study: Research | Subject: Chemical agents
Received: 2013/09/24 | Accepted: 2014/06/8 | Published: 2014/10/20
* Corresponding Author Address: Research and Clinical Center for Infertility, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Occupational Medicine Quarterly Journal

Designed & Developed by : Yektaweb