Sadeghi Naeini H, rafiei S M. Application of QFD method in toothbrush design for the cervical spinal cord injury handicapped (Tetraplegia). tkj 2018; 10 (3) :40-52
URL:
http://tkj.ssu.ac.ir/article-1-925-en.html
Iran University of Science and Technology , rafiee.mitra@yahoo.com
Full-Text [PDF 1023 kb]
(1672 Downloads)
|
Abstract (HTML) (2997 Views)
Full-Text: (1078 Views)
Application of QFD method in toothbrush design for the cervical spinal cord injury handicapped (Tetraplegia)
Sadeghi Naeini H 1(PhD), Rafiee SM2(MA)
1Department of Industrial Design, School of Architecture and Urban Planning, Iran University of Science and Technology,Tehran. Iran
2Department of Industrial Design, School of Architecture and Urban Planning, Iran University of Science and Technology,Tehran. Iran
Abstract
Introduction: The spinal cord trauma is a lost physical performance that causes physical limitations in addition to mental, social and economic disadvantages. The mouth and tooth health is known as one of the related issues to the physical quality of life. Providing the conditions of the more independence for these people in brushing teeth can improve the level of mouth and tooth hygiene. The aim of this study is offering proper patterns in designing toothbrush by emphasizing on the tetraplegia handicapped.
Methods: The results indicate, by considering the motoric limitations of spinal cord injury handicapped (C5-C7) and re-revaluating the dimensions of their palms, it should use stammer instead of grip. Also, by considering the movement rang among handicaps, the rotation of the brush set in 2 directions, brush fixation in 4 degrees and the angle between the brush and handle has been considered.
Results: The results show that the light and sanitary materials should be used in producing. The handle of toothbrush should have a little friction with the user’s hand. The pressure points should be identified and investigated, but a little pressure on hand is necessary due to grip of toothbrush.
Conclusion: It seems that in designing a product, the weight, the facility and the used material must be considered. A little pressure on hand is necessary due to grip of toothbrush.
Key words: tetraplegia, manual tools, QFD
This paper should be cited as:
Sadeghi Naeini H , Rafiee SM. Application of QFD method in toothbrush design for the cervical spinal cord injury handicapped (Tetraplegia). Occupational Medicine Quarterly Journal 2018; 10(3):40-52. |
*Corresponding Author:
Tel: +98 9122773371
Email: naeini@iust.ac.ir
Received: 2018.03.14 accepted: 2018.09.18
Type of Study:
Research |
Subject:
Ergonomics Received: 2018/03/14 | Accepted: 2019/05/4 | Published: 2019/05/4